Australia Bangladesh Brunei Cambodia China Fiji, Tonga French Polynesia Hong Kong, China India Indonesia (Bahasa) Indonesia (English) Japan Kazakhstan Korea, South Laos Malaysia Maldives Mongolia Mongolia (English) Myanmar (English) New Caledonia New Zealand Papua New Guinea Philippines Singapore Sri Lanka Taiwan, China Thailand (English) Thailand (Thai) Uzbekistan Uzbekistan (English) Vietnam Vietnam (Vietnamese)
-
Albania Austria Belarus Belarus (English) Belgium Belgium (Dutch) Bosnia-Herzegovina Bulgaria Croatia Cyprus Czech Republic Denmark Estonia Finland France Georgia Georgia (English) Germany Greece Hungary Ireland Italy Kosovo Latvia Lithuania Malta Moldavia Montenegro Netherlands North Macedonia Norway Poland Portugal Romania Russia Serbia Slovakia Slovenia Spain Sweden Switzerland (French) Switzerland (German) Turkey Ukraine (Ukrainian) United Kingdom
-
-
Algeria Azerbaijan (Azerbaijani) Azerbaijan (English) Bahrain (English) Benin Botswana Burkina Faso Cameroon Central African Republic Chad Comoros Congo Dem. Rep. Congo (Zaire) Egypt and North East Africa (Arabic) Egypt and North East Africa (English) Equatorial Guinea Francophone Africa Gabon Gambia Ghana Guinea Iraq Israel Ivory Coast Jordan Kenya Kuwait Lebanon Liberia Libya Madagascar Malawi Mali Mauritania Mauritius Mayotte Morocco Mozambique Namibia Niger Nigeria Oman Pakistan Qatar Reunion Saudi Arabia (Arabic) Saudi Arabia (English) Senegal Seychelles Sierra Leone South Africa Swaziland Tanzania Togo Tunisia Uganda United Arab Emirates Yemen Zambia Zimbabwe
-
Acti 9 Smartlink, 11 Kanäle, Modbus RS485, E/A-Kommunikationsmodul
A9XMSB11
Materialpreisgruppe
: D3
Hauptdokumente
Download | |
|
Download |
|
Download |
|
Download |
|
Download |
|
Download |
|
Download |
|
Download |
|
Download |
|
Download |
|
Download |
|
Download |
|
Download |
Spezifikationen
Hauptmerkmale | |
---|---|
Baureihe | Acti9 |
Produktsortiment | EcoStruxure |
Produktname | EcoStruxure I/O Smart Link |
Produkt- oder Komponententyp | Smart-Kommunikationsmodul |
Kurzbezeichnung des Geräts | I/O Smart Link |
Anwendungstyp | Laststeuerung Überwachung des Leistungsschalterstatus Grundlegende Energiemessung E |
Maximale Anzahl an angeschlossenen Geräten | Bis zu 11 verdrahtete Geräte |
Kanalgruppe | 1 Gruppe aus 11 digitalen Kanälen |
Max. Versorgungsstrom | 1,5 A |
[UH,nom] Bemessungsbetriebsspannung | 24 V DC +/-20 % |
Konnektivität mit Geräten | Digitaler Eingang und Ausgang Impulsausgangszähler |
Kommunikationsdienst | Modbus server für RS485 |
Webserver | Kompatibel mit GMS-Controller | Zusatzmerkmale |
anwendungspezifischer E/A | Impuls-Summenzähler Pulswechselrichter |
Schutzfunktionen | Gegen Verpolung für Hilfsspannungsversorgung Gegen Verpolung für Eingang Überspannung bei 33 V DC für Digitaler Ausgang |
Störfestigkeit gegen Unterbrechungen | 10 ms |
Rückstellung | Werksreset auf Vorderseite Muffen-Drucktaste By address encoder By plug in, plug out the power supply |
Eingangs-/Ausgangstyp | 2 Eingänge + 1 Ausgang pro digitalem Kanal |
Eingangstyp | Stromkörper für Digitaleingang, 24 V DC +/-20 % bei 2,5 mA |
max. Dauerstrom | 5 mA für Digitaleingang |
Zeit für elektronisches Filtern | 2 ms for Digitaleingang von Zustand 0 bis Zustand 1 |
Ausgangstyp | Logik-Stromquelle: 24 V - DC - 100 mA |
Maximaler Spannungsabfall | <1 V bei Status 1 Digitaler Ausgang |
Einschaltstrom | 0,5 A für Digitaler Ausgang 7 A für Stromversorgung |
Lokale Signalisierung | Kommunikation: 1 LED (gelb) Status: 1 LED (grün, orange und rot) |
Typ Einstellung | Modbus-Adresse 01 - 99 für Adressengeber Rückstellung für Adressengeber Rückstellung für Hilfsstromversorgung einstecken/ausstecken |
Einbauposition | Horizontal und vertikal auf DIN-Schiene |
Farbe | Weiß (RAL 9003) |
Position des Anschlusses | Frontseite |
Anschlüsse - Klemmen | Federzugklemme Ti24 qty: 11 for Digitaler Eingang/Ausgang, separat zu bestellen Steckverbinder qty: 1 for Versorgungsstromkreis Steckverbinder qty: 1 for Kommunikationsbus |
Klemmverbindungskapazität | 2 x 0,2 - 1,5 mm² für Twisted-Pair-Kabel (geschirmt), flexibel mit Kabelende für Kommunikationsbus 2 x 0,2 - 1,5 mm² für Twisted-Pair-Kabel (geschirmt), flexibel ohne Kabelende für Kommunikationsbus 2 x 0,2 - 1,5 mm² für Twisted-Pair-Kabel (geschirmt), fest mit Kabelende für Kommunikationsbus 2 x 0,2 - 1,5 mm² für Twisted-Pair-Kabel (geschirmt), fest ohne Kabelende für Kommunikationsbus 1 x 0,2-1 x 1,5 mm², flexibel mit Kabelende für Steuerung 1 x 0,2-1 x 1,5 mm², flexibel ohne Kabelende für Steuerung 1 x 0,2-1 x 1,5 mm², fest mit Kabelende für Steuerung 1 x 0,2-1 x 1,5 mm², fest ohne Kabelende für Steuerung 2 x 0,2 - 1,5 mm², flexibel mit Kabelende für Versorgungsstromkreis 2 x 0,2 - 1,5 mm², flexibel ohne Kabelende für Versorgungsstromkreis 2 x 0,2 - 1,5 mm², fest mit Kabelende für Versorgungsstromkreis 2 x 0,2 - 1,5 mm², fest ohne Kabelende für Versorgungsstromkreis |
Drahtabisolierungslänge | Steuerung: 10 mm Versorgungsstromkreis: 7 mm Kommunikationsbus: 7 mm |
Kommunikationsnetztyp | RS485 Modbus RTU Client/Server SUB-D 9 4.800, 9.600, 19.200 BpS, 38,4 kBit/s |
9 mm Polmittenabstand | 0 nützlich |
Höhe | 22,5 mm |
Breite | 359 mm |
Tiefe | 42 mm |
Produktgewicht | 188 g |
geliefertes Zubehör | Satz à 1 Stück Busverbinder Satz à 1 Stück Netzstecker Satz à 2 Verriegelungsclips |
Kompatible Produktfamilie | Acti 9 iTL Zusatzausrüstung Linergy Linergy FM Acti 9 iOF+SD 24 Acti 9 iACT24 Acti 9 iATL24 PowerLogic Impulsausgangszähler Acti 9 RCA iC60 Acti 9 Acti9 iCT Zusatzausrüstung Acti 9 Acti9 iC60 Acti 9 Acti9 iID Acti 9 Acti9 iSW-NA Acti 9 Acti9 iDPN Vigi Acti 9 Acti9 C40 Multi 9 Multi9 C60 Acti 9 Acti9 DT40 Acti 9 Acti9 DT60 Acti 9 Acti 9 I-NA Acti 9 Acti9 ITG40 Acti 9 Acti 9 iDPN Acti 9 Acti9 Reflex iC60 Ti24 Stecker |
Inbetriebnahme-Schnittstelle | EcoStruxure Power Commission |
Marktsegment | Gebäude Kleingewerbe |
Kompatibilitätscode | Acti 9 Smartlink | Montage |
Schutzart (IP) | IP20 |
Verschmutzungsgrad | 3 |
elektromagnetische Verträglichkeit | Widerstandsfähigkeit gegen elektrostatische Entladung (Luftaustritt), Klasse B, 8 kV, conforming to IEC 61000-4-2 Widerstandsfähigkeit gegen elektrostatische Entladung (Kontaktentladung), Klasse B, 4 kV, conforming to IEC 61000-4-2 Beständigkeit gegenüber ausgestrahlten Magnetfeldern (80 MHz - 3 GHz), Klasse A, 10 V/m, conforming to IEC 61000-4-3 Stromversorgung: Beständigkeit gegenüber ausgestrahlten Magnetfeldern (1.4…6 GHz), Klasse A, 3 V/m, conforming to IEC 61000-4-3 Stromversorgung: Festigkeit gegen Störimpuls (5 - 100 kHz), Klasse B, 2 kV, conforming to IEC 61000-4-4 Ein-/Ausgang: Festigkeit gegen Störimpuls, Klasse B, 1 kV, conforming to IEC 61000-4-4 Kommunikationsbus: Festigkeit gegen Störimpuls (0,15 - 80 MHz), Klasse B, 1 kV, conforming to IEC 61000-4-4 Leitungsgebundene elektromagnetische Verträglichkeit (0,15 - 80 MHz), Klasse A, 3 V, conforming to IEC 61000-4-6 Leitungsgebundene Emission (0,15 - 30 MHz), Klasse B, conforming to IEC 61326-1 Leitungsgebundene Emission (0,15 - 30 MHz), Klasse B, conforming to CISPR 11 Abgestrahlte Emission (30...6000 MHz), Klasse B, conforming to IEC 61326-1 Abgestrahlte Emission (30...6000 MHz), Klasse B, conforming to CISPR 11 Stromversorgung: Stoßspannungen (DM coupling 42 Ohm), Klasse B, 1 kV, conforming to IEC 61000-4-5 Stromversorgung: Stoßspannungen (CM coupling 42 Ohm), Klasse B, 2 kV, conforming to IEC 61000-4-5 Kommunikationsbus: Stoßspannungen (CM coupling 2 Ohm), Klasse B, 1 kV, conforming to IEC 61000-4-5 |
Umgebungseigenschaften | Korrosiv 3C2 entspricht IEC 60721-3-3 Salznebel 2 entspricht IEC 60068-2-52 |
Vibrationsfestigkeit | 1 Gn, Amplitude = 3,5 mm (f = 5…300 Hz)10 Zyklen entspricht EN/IEC 60068-2-6 |
Stoßfestigkeit | 15 Gn für 11 ms entspricht IEC 60068-2-27 |
Feuerbeständigkeit | Andere Bauteile: 650 °C ( 30 s ) entspricht IEC 60695-2-10 Auf Anschlussklemmen: 960 °C ( 30 s ) entspricht IEC 60695-2-10 |
Tropentauglichkeit | 2 |
Relative Luftfeuchtigkeit | 0…93 % bei 40 °C |
Aufstellungshöhe | 0 - 2.000 m |
Umgebungstemperatur bei Betrieb | -25…60 °C |
Umgebungstemperatur bei Lagerung | -40…85 °C |
Schutzart (IK) | IK06 entspricht IEC 62262 |
Normen | IEC 61010-2-201 IEC 61010-1 |
Verpackungseinheiten |
VPE 1 Art | PCE |
VPE 1 Menge | 1 |
VPE 1 Gewicht | 242,000 g |
VPE 1 Höhe | 3,300 cm |
VPE 1 Breite | 6,500 cm |
VPE 1 Länge | 37,000 cm |
VPE 2 Art | S03 |
VPE 2 Menge | 32 |
VPE 2 Gewicht | 8,200 kg |
VPE 2 Höhe | 30,000 cm |
VPE 2 Breite | 30,000 cm |
VPE 2 Länge | 40,000 cm | Vertragliche Gewährleistung |
Gewährleistung | 18 months |
Nachhaltigkeit
Environmental data
EU-RoHS-Richtlinie
|
Konform mit Ausnahme EU-RoHS-Deklaration |
Quecksilberfrei
|
Ja |
SCIP-Nummer | 2c4a7f95-9fbf-4b2e-bc7e-82ceeb851894 |
Verpackung ohne Kunststoff | Nein |
Verpackung mit Recycling-Karton | Nein |
Rücknahme | No |
CO2-Bilanz (kg CO2 eq.) | 35 |
Global warming ; Total life cycle | 35 kg CO2 eq. |
46 Dokumente
Présentation PowerTag : Systéme de surveillance et de gestion énergétique sans fil
15/04/25 · Brochure |
14,5 MB | Download |
Auswahlkatalog 2024
08/04/25 · Catalog |
47,5 MB | Download |
Wireless-Kommunikationsarchitekturen mit EcoStruxure Panel Server - Designrichtlinien
07/04/25 · User guide |
6,7 MB | Download |
A9XMSB11 REACh-Erklärung
07/04/25 · Declaration of Conformity (Sustainability) |
0,2 MB | Download |
A9XMSB11 EU-RoHS-Erklärung
07/04/25 · Declaration of Conformity (Sustainability) |
0,2 MB | Download |
A9XMSB11 China-RoHS-Erklärung
07/04/25 · Declaration of Conformity (Sustainability) |
0,2 MB | Download |
EcoStruxure Power - Smart Panel Assembly Guide for commercial and industrial buildings (2025 EN) - Technical guide
02/04/25 · Other technical guide |
1,1 MB | Download |
EcoStruxure I/O Smart Link, Environmental Disclosure, Product Environmental Profile 15/03/25 · Environmental Disclosure | 0,4 MB | Download |
EcoStruxure I/O Smart Link, Circularity Profile, End of Life Instructions 15/03/25 · Circularity Profile | 0,3 MB | Download |
EcoStruxure I/O Smart Link - Note della versione del firmware
15/03/25 · Firmware - History, Utility & Others |
0,3 MB | Download |
EcoStruxure I/O Smart Link - Guía de usuario
15/03/25 · User guide |
4,8 MB | Download |
EcoStruxure I/O Smart Link - Guida utente
15/03/25 · User guide |
4,8 MB | Download |
EcoStruxure I/O Smart Link - Notas de la versión del firmware
15/03/25 · Firmware - History, Utility & Others |
0,3 MB | Download |
EcoStruxure I/O Smart Link - Notes de publication du logiciel embarqué
15/03/25 · Firmware - History, Utility & Others |
0,3 MB | Download |
EcoStruxure I/O Smart Link - Manuel utilisateur
15/03/25 · User guide |
4,8 MB | Download |
EcoStruxure I/O Smart Link - User Guide
15/03/25 · User guide |
4,8 MB | Download |
EcoStruxure I/O Smart Link - A9XMSB11 - Gebrauchsanleitung 15/03/25 · Instruction sheet | 15,6 MB | Download |
EcoStruxure I/O Smart Link - Firmware Release Notes
15/03/25 · Firmware - History, Utility & Others |
0,3 MB | Download |
EU Declaration of Conformity 15/03/25 · Declaration of conformity | 0,5 MB | Download |
DoC DEcomm interfaces 15/03/25 · Declaration of conformity | 1,0 MB | Download |
Acti9 Smartlink Modbus - 3D CAD 15/03/25 · CAD | 6,3 MB | Download |
Diagnostic du Système de Communication Acti9 - Manuel utilisateur 15/03/25 · User guide | 0,7 MB | Download |
Sistema de comunicación Acti9 Smartlink Ethernet - Manual del usuario 15/03/25 · User guide | 20,2 MB | Download |
Sistema di comunicazione Acti9 Smartlink Modbus - Manuale utente 15/03/25 · User guide | 11,3 MB | Download |
Sistema di comunicazione Acti9 Smartlink Ethernet - Manuale utente 15/03/25 · User guide | 20,0 MB | Download |
Système de communication Acti9 Smartlink Modbus - Manuel utilisateur 15/03/25 · User guide | 11,3 MB | Download |
Sistema de comunicaciones Acti9 Smartlink Modbus - Manual del usuario 15/03/25 · User guide | 11,6 MB | Download |
Acti9 Système de communication Smartlink Ethernet - Manuel d’utilisation 15/03/25 · User guide | 20,5 MB | Download |
Système PowerTag - Guide de conception et de mise en service 15/03/25 · User guide | 14,2 MB | Download |
Katalog 2021 ComPacT NSX & NSXm 15/03/25 · Catalog | 44,7 MB | Download |
Installationsgeräte 15/03/25 · Catalog | 36,5 MB | Download |
A9XMSB11 - Technical Product Datasheet 15/03/25 · Data Bulletin | 0,1 MB | Download |
Acti9 Smartlink Modbus - User Manual 15/03/25 · User guide | 0,7 MB | Download |
Acti9 Smartlink Ethernet Communication System - User Manual 15/03/25 · User guide | 19,3 MB | Download |
PowerTag System - Design and Commissioning Guide 15/03/25 · User guide | 14,4 MB | Download |
Acti 9 Smartlink Modbus Communication System - User Manual 15/03/25 · User guide | 11,2 MB | Download |
Acti 9 Smartlink - A9XMSB11- Gebrauchsanleitung 15/03/25 · Instruction sheet | 6,2 MB | Download |
Smart panels - communication switchboards assembly - technical guide 15/03/25 · Other technical guide | 55,5 MB | Download |
EcoStruxure I/O Smart Link - Benutzerhandbuch
27/02/25 · User guide |
4,8 MB | Download |
EcoStruxure I/O Smart Link - Firmware-Versionshinweise
15/02/25 · Firmware - History, Utility & Others |
0,3 MB | Download |
UK Declaration of conformity 15/02/25 · Declaration of conformity | 0,2 MB | Download |
Kommunikationssystem Acti9 Smartlink Ethernet - Benutzerhandbuch 15/02/25 · User guide | 20,2 MB | Download |
Ensuring the satisfactory functioning of loads critical for human protection 15/02/25 · Application Notes | 0,3 MB | Download |
Kommunikationssystem Acti9 Smartlink Modbus Benutzerhandbuch 20/01/25 · User guide | 11,1 MB | Download |
EU Declaration - FD16051101A Acti 9 Smartlink A9XMEA08 20/01/25 · Declaration of conformity | 0,3 MB | Download |
Assurer le bon fonctionnement des charges critiques pour la sécurité des personnes 20/01/25 · Application Notes | 0,4 MB | Download |