Select your location
-
Most Common Destinations
-
Asia Pacific
Australia Bangladesh Brunei Cambodia China Fiji, Tonga French Polynesia Hong Kong, China India Indonesia (Bahasa) Indonesia (English) Japan Kazakhstan Korea, South Laos Malaysia Maldives Mongolia Mongolia (English) Myanmar (English) New Caledonia New Zealand Papua New Guinea Philippines Singapore Sri Lanka Taiwan, China Thailand (English) Thailand (Thai) Uzbekistan Uzbekistan (English) Vietnam Vietnam (Vietnamese) -
Europe
Albania Austria Belarus Belarus (English) Belgium Belgium (Dutch) Bosnia-Herzegovina Bulgaria Croatia Cyprus Czech Republic Denmark Estonia Finland France Georgia Georgia (English) Germany Greece Hungary Ireland Italy Kosovo Latvia Lithuania Malta Moldavia Montenegro Netherlands North Macedonia Norway Poland Portugal Romania Russia Serbia Slovakia Slovenia Spain Sweden Switzerland (French) Switzerland (German) Turkey Ukraine (Ukrainian) United Kingdom -
Latin America
-
Middle East and Africa
Algeria Azerbaijan (Azerbaijani) Azerbaijan (English) Bahrain (English) Benin Botswana Burkina Faso Cameroon Central African Republic Chad Comoros Congo Dem. Rep. Congo (Zaire) Egypt and North East Africa (Arabic) Egypt and North East Africa (English) Equatorial Guinea Francophone Africa Gabon Gambia Ghana Guinea Iraq Israel Ivory Coast Jordan Kenya Kuwait Lebanon Liberia Libya Madagascar Malawi Mali Mauritania Mauritius Mayotte Morocco Mozambique Namibia Niger Nigeria Oman Pakistan Qatar Reunion Saudi Arabia (Arabic) Saudi Arabia (English) Senegal Seychelles Sierra Leone South Africa Swaziland Tanzania Togo Tunisia Uganda United Arab Emirates Yemen Zambia Zimbabwe -
North America
MGE Galaxy 5500, 100 kVA, 400–415 V, Einzel-USV, Marine, IP22, RAL 7035, Start-up-Service 5x8
G55TUPU100HMS
Spezifikationen
| Übersicht | |
|---|---|
| Ausführung | Die USV entspricht den Anforderungen für Standard-Marineausrüstungen. | Hauptmerkmale |
| Main input voltage | 400 V |
| Other input voltage | 380 V 400 V 415 V |
| Output voltage | 400 V 3 Phasen |
| Other output voltage | 380 V |
| Rated power in W | 90000 W |
| Rated power in VA | 100000 VA |
| Output connection | Fest verdrahtet 4-adrig (3P + E) for 1 zone(s) |
| Input frequency | 45 - 65 Hz |
| Input connection | 1 fest verdrahtet 4-adrig (3P + E) 1 fest verdrahtet 4-adrig (3-phasig + N) |
| Efficiency at full load | 323 - 437 V 380 V 340 - 460 V 400 V 353 - 477 V 415 V |
| Maximum input current | 190 A |
| Switching current capacity | 250 A |
| Max short time withstand current | 30 kA |
| Input harmonic distortion | Weniger als 3 % bei Volllast |
| Input protection | GL-Sicherung |
| Load power factor | 0.9 |
| Cos phi | 1 |
| Maximum configurable power in W | 90000 W |
| Harmonic distortion | Weniger als 2 % |
| Output frequency | 50 Hz programmierbar +/- 0,5 / 1 / 2 / 4 / 6 / 8 % Netzsynchronisation 50 Hz +/-0,1 % für 50 Hz Nominal nicht synchronisiert |
| Crest factor | 3:1 |
| Waveform type | Sinuswelle |
| Output voltage tolerance | +/-2 % statisch und 100 % Last |
| Output harmonic distortion | < 1% linear load and < 2.5% non-linear load |
| Output overload operation | 10 Minuten bei 125 % und 60 Sekunden bei 150 % |
| Required output current protection | 144 A |
| Neutral output current | 217 A |
| Bypass type | Integrierter Wartungsbypass Integrierter statischer Bypass Optionaler externer Bypass |
| Efficiency | 93 % (Volllast) 91 % (Halblast) |
| Maximum output current | 480 A |
| Maximum configurable power in VA | 100000 VA |
| Main input voltage | 400 V | Batterien und Überbrückungszeit |
| Battery type | Externes Batteriesystem |
| Battery charging power | 9300 W bewertet |
| Battery life | 8…10 Jahre | Zusatzmerkmale |
| Provided equipment | Installationsanleitung Benutzerhandbuch |
| Bypass wiring configuration | 4-drahtig (3-phasig + N) 5 Leiter (3 PH + N + PE) |
| Bypass voltage tolerance | +/-10 % einstellbar von +/-4/6/8 bis 10 % |
| Max bypass input current | 144 A |
| Bypass current protection | 200 A |
| Redundant | No |
| Height | 221 cm |
| Width | 71,2 cm |
| Depth | 85,5 cm |
| Product weight | 588 kg |
| Mounting preference | No preference |
| USB compatible | No |
| Additional information | Konfigurierbar für 380, 400 oder 415 V 3-phasige Nennausgangsspannung |
| Free slot | 3 |
| Preinstalled device | Network management card 2 with environmental monitoring, out of band access and Modbus - Schneider |
| Control panel | Multifunktionale LCD-Status- und Steuerungskonsole |
| Emergency power off | Ja | Montage |
| Product certification | TÜV |
| Standard | EN/IEC 62040-3 |
| Ambient air temperature for operation | 0…40 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 0 - 3.333 ft |
| Ambient air temperature for storage | -20…45 °C |
| Storage relative humidity | 0…95 % |
| Storage altitude | 0…12192 m |
| Acoustic level | 63 dBA |
| IP protection | IP20 | Verpackungseinheiten |
| Verpackungsgewicht (Lbs) | 610 kg |
| VPE 1 Höhe | 233 cm |
| VPE 1 Breite | 120 cm |
| VPE 1 Länge | 108 cm |
| VPE 1 Art | PCE |
| Anzahl der Geräte pro Packung | 1 | Vertragliche Gewährleistung |
| Garantie (in Monaten) | 12 |
Nachhaltigkeit
Nachhaltigkeit
| Sustainable packaging | Nein |
| WEEE-Kennzeichnung | Das Produkt muss entsprechend bestimmter Hinweise auf Märkten der Europäischen Union entsorgt werden und darf nicht in Haushaltsabfälle gelangen. |
17 Dokumente
| MGE Galaxy 5500 20-120 kVA 400 V Safety and Handling 15/03/25 · User guide | 0,5 MB | Download |
| MGE Galaxy 5500 20-120 kVA 400 V Safety and Handling 15/03/25 · User guide | 0,5 MB | Download |
| Galaxy 5500 20-120 kVA 400 V Installation 15/03/25 · User guide | 7,2 MB | Download |
| Galaxy 5500 20-120 kVA, 400 V - Installazione 15/03/25 · User guide | 7,5 MB | Download |
| Galaxy 5500 20 - 120 kVA 400 V Instalación 15/03/25 · User guide | 7,5 MB | Download |
| Galaxy 5500 Marine / Off Shore Receiving and Unpacking
15/03/25 · User guide |
3,6 MB | Download |
| MGE Galaxy 5500 20-120 kVA 400 V Safety and Handling 15/03/25 · User guide | 0,4 MB | Download |
| Modbus Register Map for TCP IP- MGE Galaxy 5500
15/03/25 · User guide |
0,0 MB | Download |
| Galaxy 5500 20 - 120 kVA 400 V Installation
15/03/25 · User guide |
7,4 MB | Download |
| Schneider Electric - Wichtige Sicherheitsanweisungen
15/03/25 · User guide |
1,1 MB | Download |
| MGE Galaxy 5500 20-120 kVA 400 V Safety and Handling 15/03/25 · User guide | 0,5 MB | Download |
| Galaxy 5500/Galaxy 5500 Marine 20 - 120 kVA 400 V Installation 15/03/25 · User guide | 7,5 MB | Download |
| G55TUPU80K120HBOTC1-SD - MGE Galaxy 5500 Offshore & Marine 80-120kVA UPS 1MOD with Battery & Output XFMR System One Line
15/03/25 · Technical Drawing |
0,4 MB | Download |
| G55TUPU80K120HBC1-SD - MGE Galaxy 5500 Offshore & Marine 80-120kVA UPS 1MOD with Battery Cabinet System One Line
15/03/25 · Technical Drawing |
0,3 MB | Download |
| G55TUPU20K120HC1-WD – MGE Galaxy 5500 Offshore & Marine 20-120kVA UPS 1MOD Wiring Diagram
15/03/25 · Technical Drawing |
0,2 MB | Download |
| G55TUP20K120HMS - MGE Galaxy 5500 20-120kVA 400-415V UPS Marine IP22
20/01/25 · Technical Drawing |
1,2 MB | Download |
| MGE Galaxy 5500 20-120 kVA 400 V Safety and Handling 19/01/25 · User guide | 0,5 MB | Download |