Select your location

Galaxy VS USV 150 kW 400 V für externe Batterien, halogenfreie Kabel, Marine zertifiziert, Start-up 5x8

GVSUPS150KMHS

Hauptdokumente

Produktdatenblatt Download
Technical Drawing Download
Specification guide Download
Brochure Download
Certificate of Origin Download
Declaration of conformity Download
Declaration of Conformity (Sustainability) Download
User guide Download
Catalog Download
Circularity Profile Download
Firmware Download
Environmental Disclosure Download

Spezifikationen

Übersicht
Ausführung Highly efficient, fast-to-deploy 150kW, 400V 3-phase UPS that brings best-in-class power protection and low total cost of ownership to edge, small and medium data centers, as well as to critical infrastructure in commercial and industrial applications. Includes 5x8 start-up service and halogen-free cables. Marine certified.
Hauptmerkmale
Main input voltage 380 V
Other input voltage 380 V
415 V
Output voltage 380 V
Rated power in W 150 kW
Rated power in VA 150 kVA
Input frequency 40 - 70 Hz
Efficiency at full load 340 - 460 V 400 V
Maximum input current 270 A
Max short time withstand current 65 kA
Input harmonic distortion Weniger als 3 % bei Volllast
Load power factor Von 0,7 kapazitiv bis 0,7 induktiv ohne leistungsreduzierung
Maximum configurable power in W 150 kW
Output frequency 50 Hz Netzsynchronisation
60 Hz Netzsynchronisation
50 Hz +/-0,1 % für 50 Hz Nominal nicht synchronisiert
60 Hz +/-0,1 % für 60 Hz Nominal nicht synchronisiert
Crest factor 2,5
Waveform type Sinuswelle
Output voltage tolerance +/-1 % nach 50 ms
Output harmonic distortion < 1% linear load and < 5% non-linear load
Output overload operation 10 Minuten bei 125 % und 60 Sekunden bei 150 %
Bypass type Integrierter statischer Bypass
Maximum configurable power in VA 150 kVA
Main input voltage 415 V
Output voltage 415 V
Batterien und Überbrückungszeit
Battery type Li-Ion (Lithium-Ionen)
Battery voltage 480 - 576 V DC
Discharge battery voltage 384 V DC
Zusatzmerkmale
Provided equipment Staubfilter
Vorbereitet für EcoStruxure IT (USV)
Installationsanleitung
Integriertes Netzwerkmanagement
Leistungsmodule werden installiert geliefert
Inbetriebnahme-Service
Bypass voltage tolerance +/- 10 %
Redundant No
Color Weiß
Height 148,5 cm
Width 52,1 cm
Depth 84,7 cm
Product weight 290 kg
USB compatible No
Max current discharge 407 A
Control panel LCD-Benutzeroberfläche mit Touchscreen
Range of product Galaxy VS
Product or component type Unterbrechungsfreie Stromversorgung
Battery type Blei-Säure external sold separately
Li-Ion (Lithium-Ionen) external sold separately
UPS connectivity Embedded network management card 4
Color Weiß
Montage
Standard IEC 60721-4-2 Level 2M2
Ambient air temperature for operation 0…40 °C
Relative humidity 0…95 % nicht kondensierend
Operating altitude 0 - 3.300 ft
Ambient air temperature for storage -25…55 °C
Storage relative humidity 10…80 % nicht kondensierend
Acoustic level 68 dBA
IP protection IP21
Heat dissipation 16900 Btu/h
Verpackungseinheiten
Verpackungsgewicht (Lbs) 330 kg
VPE 1 Höhe 168 cm
VPE 1 Breite 99 cm
VPE 1 Länge 64 cm
VPE 1 Art PCE
Anzahl der Geräte pro Packung 1
Vertragliche Gewährleistung
Garantie (in Monaten) 12

Nachhaltigkeit

Nachhaltigkeit
Verpackung ohne Kunststoff Nein
Verpackung mit Recycling-Karton Ja
Rücknahme Ja
Sustainable packaging Nein
WEEE-Kennzeichnung Das Produkt muss entsprechend bestimmter Hinweise auf Märkten der Europäischen Union entsorgt werden und darf nicht in Haushaltsabfälle gelangen.
EU-RoHS-Richtlinie https://download.se.com/files?p_Doc_Ref=GVSUPS150KMHS_ROHS_DECLARATION&p_enDocType=Declaration+of+Conformity+%28Sustainability%29
REACh-Verordnung https://download.se.com/files?p_Doc_Ref=GVSUPS150KMHS_REACH_DECLARATION&p_enDocType=Declaration+of+Conformity+%28Sustainability%29
Total lifecycle Carbon footprint 154 ton CO2 eq.
Carbon footprint of the manufacturing phase [A1 to A3] 3126
CO₂-Fußabdruck der Herstellungsphase [A1 bis A3] 3 126 kg CO2 eq.
Carbon footprint of the distribution phase [A4] 42.5772
CO₂-Fußabdruck der Distributionsphase [A4] 43 kg CO2 eq.
Carbon footprint of the installation phase [A5] 19.5588
CO₂-Fußabdruck der Installationsphase [A5] 20 kg CO2 eq.
Carbon footprint of the use phase [B2, B3, B4, B6] 151178.961038961
CO₂-Fußabdruck der Nutzungsphase [B2, B3, B4, B6] 151 ton CO2 eq.
Carbon footprint of the end-of-life phase [C1 to C4] 112.4712
CO₂-Fußabdruck der End-of-Life-Phase [C1 bis C4] 112 kg CO2 eq.
CO2-Bilanz (kg CO2 eq.) 154480

Dokumente

Aktueller Filter
  • Dokumentenkategorie
  • Sprache
28 Dokumente
USV-Lösungen, Racks und PDUs - Katalog 2025
15/09/25 · Catalog
8,6 MB Download
Galaxy VS UPS for External Batteries and UPS with Internal Batteries Up to 2 or 4 Battery Strings Receiving and Unpacking
03/04/25 · User guide
3,7 MB Download
GVSUPS150KMHS REACh-Erklärung
20/03/25 · Declaration of Conformity (Sustainability)
0,2 MB Download
GVSUPS150KMHS EU-RoHS-Erklärung
20/03/25 · Declaration of Conformity (Sustainability)
0,2 MB Download
APC PowerNet MIB 15/03/25 · Firmware 2,9 MB Download
End of Life instructions for Galaxy VS_EN 15/03/25 · Circularity Profile 0,6 MB Download
Network Management Card 4 (NMC 4) Galaxy VS Firmware 6.118.0 Release Notes 15/03/25 · User guide 0,3 MB Download
Galaxy VS ASI pour batteries externes Installation
15/03/25 · User guide
10,1 MB Download
UKCA Declaration of Conformity for Galaxy VS 15/03/25 · Declaration of conformity 0,3 MB Download
Galaxy VS 400 V Certificate of Origin 15/03/25 · Certificate of Origin 0,1 MB Download
Galaxy VS Operation manual 15/03/25 · User guide 3,7 MB Download
Network Management Card 4 - Installation Guide
15/03/25 · User guide
1,6 MB Download
Network Management Card 4 Security Handbook 15/03/25 · User guide 0,8 MB Download
Befehlszeilenhandbuch USV-Netzwerkmanagement-Karte 4
15/03/25 · User guide
1,4 MB Download
Network Management Card 4 - Feature List
15/03/25 · User guide
0,2 MB Download
Galaxy VS UPS Systems Earthing Principles
15/03/25 · User guide
8,8 MB Download
Galaxy VS 10-150 kW UPS for External Batteries Installation Manual
15/03/25 · User guide
10,2 MB Download
Befehlszeilenhandbuch für USV-Netzwerkmanagement-Karte 4
15/03/25 · User guide
0,6 MB Download
USV-Netzwerkmanagement-Karte 4 - Installationshandbuch
15/03/25 · User guide
1,3 MB Download
Galaxy VS 10-150kW 400V Brochure
15/03/25 · Brochure
7,0 MB Download
Battery Runtime Chart: Galaxy VS 20-150 kW UPS with Classic Battery Cabinet or Modular Battery Cabinet 400V
15/03/25 · Specification guide
0,1 MB Download
Galaxy VS UPS for External Batteries Technical Specifications 20-150 kW 400/440 V
15/03/25 · Specification guide
1,8 MB Download
GVSOPT027-Galaxy VS Mounting Skid for 52mm wide UPS_Battery Marine or Industrial Applications
15/03/25 · Technical Drawing
1,0 MB Download
GVSUPS20K150KMHS-Galaxy_VS_Marine_20-150kW_UPS_3Ph_400V_without_Batteries
15/03/25 · Technical Drawing
0,7 MB Download
Galaxy VS EU Declaration of Conformity
15/03/25 · Declaration of conformity
0,4 MB Download
01/01/70 User guide 0,0 MB Download
01/01/70 Environmental Disclosure 0,0 MB Download
01/01/70 User guide 0,0 MB Download