Select your location
-
Most Common Destinations
-
Asia Pacific
Australia Bangladesh Brunei Cambodia China Fiji, Tonga French Polynesia Hong Kong, China India Indonesia (Bahasa) Indonesia (English) Japan Kazakhstan Korea, South Laos Malaysia Maldives Mongolia Mongolia (English) Myanmar (English) New Caledonia New Zealand Papua New Guinea Philippines Singapore Sri Lanka Taiwan, China Thailand (English) Thailand (Thai) Uzbekistan Uzbekistan (English) Vietnam Vietnam (Vietnamese) -
Europe
Albania Austria Belarus Belarus (English) Belgium Belgium (Dutch) Bosnia-Herzegovina Bulgaria Croatia Cyprus Czech Republic Denmark Estonia Finland France Georgia Georgia (English) Germany Greece Hungary Ireland Italy Kosovo Latvia Lithuania Malta Moldavia Montenegro Netherlands North Macedonia Norway Poland Portugal Romania Russia Serbia Slovakia Slovenia Spain Sweden Switzerland (French) Switzerland (German) Turkey Ukraine (Ukrainian) United Kingdom -
Latin America
-
Middle East and Africa
Algeria Azerbaijan (Azerbaijani) Azerbaijan (English) Bahrain (English) Benin Botswana Burkina Faso Cameroon Central African Republic Chad Comoros Congo Dem. Rep. Congo (Zaire) Egypt and North East Africa (Arabic) Egypt and North East Africa (English) Equatorial Guinea Francophone Africa Gabon Gambia Ghana Guinea Iraq Israel Ivory Coast Jordan Kenya Kuwait Lebanon Liberia Libya Madagascar Malawi Mali Mauritania Mauritius Mayotte Morocco Mozambique Namibia Niger Nigeria Oman Pakistan Qatar Reunion Saudi Arabia (Arabic) Saudi Arabia (English) Senegal Seychelles Sierra Leone South Africa Swaziland Tanzania Togo Tunisia Uganda United Arab Emirates Yemen Zambia Zimbabwe -
North America
APC Back-UPS 750 VA, 230 V, Tower, AVR, 4 IEC C13 Ausgänge
BX750MI
Hauptdokumente
| Download | |
|
|
Download |
|
|
Download |
|
|
Download |
|
|
Download |
|
|
Download |
|
|
Download |
|
|
Download |
|
|
Download |
|
|
Download |
|
|
Download |
|
|
Download |
Dieses Produkt ist kompatibel mit
Ersatzbatterien: Kompatible Produkte
Ersatzbatterien (1)
Spezifikationen
| Übersicht | |
|---|---|
| Lieferzeit | Normalerweise auf Lager | Hauptmerkmale |
| Haupteingangsspannung | 230 V AC 1 Phase |
| Bemessungsleistung in W | 410 W |
| Nennleistung in VA | 750 VA |
| Anschlussart der Ausgänge | 4 IEC 60320 C13 |
| Netzwerkfrequenz | 50/60 Hz +/-5 Hz automatische Erfassung |
| Eingangsspannungsgrenzen | 140 - 300 V |
| Cos phi | 0,63 |
| Max. konfigurierbare Leistung in W | 410 W |
| Ausgangsfrequenz | 50/60 Hz +/-1 Hz Netzsynchronisation |
| USV-Typ | Line Interactive |
| Wellentyp | Stufenweise Annäherung an eine Sinuswelle |
| Laufzeit bei Volllast | 00:01:00 390 W |
| Laufzeit bei Halblast | 00:08:30 195 W |
| Max. konfigurierbare Leistung in VA | 750 VA |
| Umschaltzeit | 6 ms typisch, 10 ms max. |
| Anschlussart der Eingänge | IEC 60320 C13 |
| Steckernorm | C14 |
| USB Charging Port | None | Zusatzmerkmale |
| Kabellänge | 1,2 m |
| Anzahl von Kabeln | 1 |
| Redundant | No |
| Farbe | Schwarz |
| Höhe | 160 mm |
| Breite | 120 mm |
| Tiefe | 355 mm |
| Produktgewicht | 5,4 kg |
| Montagepräferenz | No preference |
| Montagemodus | Nicht Rack-montierbar |
| USB-kompatibel | Yes |
| Batteriekapazität | 7,0 AH |
| Bedienfeld | LED Statusanzeige mit On-Line: Batteriebetrieb |
| Anstieg der Energiemenge | 273 J |
| Produkt- oder Komponententyp | Unterbrechungsfreie Stromversorgung (USV) |
| Baureihe | Back-UPS |
| UPS connectivity | None |
| Battery type | Lead-acid internal included |
| Montagemodus | Tower | Batterien und Überbrückungszeit |
| Batterietyp | Bleisäurebatterie |
| Aufladezeit der Batterie | 8 h |
| Batteriespannung | 12 V |
| Batterielebensdauer | 3…5 Jahre |
| Kommentare zum Batteriediagramm | Kurve wurde an die gemessenen Autonomiezeiten angepasst. Alle Messungen wurden mit neuen, voll geladenen Batterien unter typischen Umgebungsbedingungen ohne Eingangsleistung und einer ohmschen Ausgangsbelastung (korrigierter Leistungsfaktor von 1,0) vorge | Montage |
| Produktzertifizierungen | CE CB EAC |
| Umgebungstemperatur bei Betrieb | 0…40 °C |
| Relative Luftfeuchtigkeit | 0…95 % nicht kondensierend |
| Betriebshöhe | 0 - 3.000 m |
| Umgebungstemperatur bei Lagerung | -15…40 °C |
| Relative Feuchtigkeit bei Lagerung | 0…95 % nicht kondensierend |
| Aufbewahrungshöhe | 0…3000 m |
| Geräuschpegel | 40 dBA |
| Schutzart (IP) | IP20 |
| Normen | EN/IEC 62040-1:2019/A11:2021 EN/IEC 62040-2:2006/AC:2006 EN/IEC 62040-2:2018 |
Verpackungseinheiten |
| Verpackungsgewicht (Lbs) | 5,9 kg |
| VPE 1 Höhe | 25 cm |
| VPE 1 Breite | 43 cm |
| VPE 1 Länge | 19,7 cm |
| SCC14 | 10731304410796 |
| VPE 1 Art | PCE |
| Anzahl der Geräte pro Packung | 1 |
| Verpackungseinheiten pro Palettenlage | 12 |
| Palettenlagen | 8 | Vertragliche Gewährleistung |
| Garantie (in Monaten) | 24 |
Nachhaltigkeit
Nachhaltigkeit
| Frei von giftigen Schwermetallen | Ja |
|
Quecksilberfrei
|
Ja |
| SCIP-Nummer | Ec96232c-7000-4722-846e-a372cdfca8dc |
| Verpackung ohne Kunststoff | Nein |
| Verpackung mit Recycling-Karton | Nein |
| Rücknahme | Ja |
| Sustainable packaging | Nein |
| WEEE-Kennzeichnung | Das Produkt muss entsprechend bestimmter Hinweise auf Märkten der Europäischen Union entsorgt werden und darf nicht in Haushaltsabfälle gelangen. |
| Total lifecycle Carbon footprint | 210 kg CO2 eq. |
| Carbon footprint of the manufacturing phase [A1 to A3] | 56.53272727272727 |
| CO₂-Fußabdruck der Herstellungsphase [A1 bis A3] | 57 kg CO2 eq. |
| Carbon footprint of the distribution phase [A4] | 0.6093090909090909 |
| CO₂-Fußabdruck der Distributionsphase [A4] | 0.6 kg CO2 eq. |
| CO₂-Fußabdruck der Installationsphase [A5] | 0 kg CO2 eq. |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 152.3272727272727 |
| CO₂-Fußabdruck der Nutzungsphase [B2, B3, B4, B6] | 152 kg CO2 eq. |
| Carbon footprint of the end-of-life phase [C1 to C4] | 0.5374363636363636 |
| CO₂-Fußabdruck der End-of-Life-Phase [C1 bis C4] | 0.5 kg CO2 eq. |
| CO2-Bilanz (kg CO2 eq.) | 210 |
| EU-RoHS-Richtlinie | https://download.schneider-electric.com/files?p_Doc_Ref=BX750MI_ROHS_DECLARATION&p_enDocType=Declaration+of+Conformity+%28Sustainability%29 |
| REACh-Verordnung | https://download.schneider-electric.com/files?p_Doc_Ref=BX750MI_REACH_DECLARATION&p_enDocType=Declaration+of+Conformity+%28Sustainability%29 |
| Recyclingfähigkeitspotential in % | 62 |
22 Dokumente
| USV-Lösungen, Racks und PDUs - Katalog 2025
15/09/25 · Catalog |
8,6 MB | Download |
| BX750MI REACh-Erklärung
04/04/25 · Declaration of Conformity (Sustainability) |
0,2 MB | Download |
| BX750MI EU-RoHS-Erklärung
04/04/25 · Declaration of Conformity (Sustainability) |
0,2 MB | Download |
| APC Medium Back-UPS Promo 15/03/25 · Brochure | 2,4 MB | Download |
| Argentina IRAM certificate APC Back-UPS 750 950 VA, 230V, AVR, Argentina Sockets
15/03/25 · Certificate |
0,3 MB | Download |
| End of Life instructions for BACK UPS _EN 15/03/25 · Circularity Profile | 0,5 MB | Download |
| CB certificate BX BVX 750 900 950 230V
15/03/25 · Certificate |
0,3 MB | Download |
| EMC BX750.950MI, BVX900LI
15/03/25 · Certificate |
0,3 MB | Download |
| User Manual for BX Series 500/750/950/1200/1600/2200 VA 15/03/25 · User guide | 1,0 MB | Download |
| Back-UPS BX-MI (IEC) Brochure
15/03/25 · Brochure |
0,4 MB | Download |
| Back UPS BX Series 230V Brochure
15/03/25 · Brochure |
0,5 MB | Download |
| User Manual for BX Series 500/750/950/1200/1600/2200 VA
15/03/25 · User guide |
1,3 MB | Download |
| CE DOC Easy UPS
15/03/25 · Declaration of conformity |
0,2 MB | Download |
| UKCA Declaration of Conformity 992-9420
15/03/25 · Declaration of conformity |
0,4 MB | Download |
| Consumer Guarantee- 2 Yrs for EU
15/03/25 · Warranty |
0,1 MB | Download |
| Consumer Guarantee - 2 Yrs for EU 15/03/25 · Warranty | 0,1 MB | Download |
| 01/01/70 Safety Data Sheet (SDS or MSDS) | 0,0 MB | Download |
| 01/01/70 Safety Data Sheet (SDS or MSDS) | 0,0 MB | Download |
| 01/01/70 Environmental Disclosure | 0,0 MB | Download |
| 01/01/70 Safety Data Sheet (SDS or MSDS) | 0,0 MB | Download |
| 01/01/70 Software - Release | 0,0 MB | Download |
| 01/01/70 Brochure | 0,0 MB | Download |
Softwares