Select your location
-
-
Australia Bangladesh Brunei Cambodia China Fiji, Tonga French Polynesia Hong Kong, China India Indonesia (Bahasa) Indonesia (English) Japan Kazakhstan Korea, South Laos Malaysia Maldives Mongolia Mongolia (English) Myanmar (English) New Caledonia New Zealand Papua New Guinea Philippines Singapore Sri Lanka Taiwan, China Thailand (English) Thailand (Thai) Uzbekistan Uzbekistan (English) Vietnam Vietnam (Vietnamese)
-
Albania Austria Belarus Belarus (English) Belgium Belgium (Dutch) Bosnia-Herzegovina Bulgaria Croatia Cyprus Czech Republic Denmark Estonia Finland France Georgia Georgia (English) Germany Greece Hungary Ireland Italy Kosovo Latvia Lithuania Malta Moldavia Montenegro Netherlands North Macedonia Norway Poland Portugal Romania Russia Serbia Slovakia Slovenia Spain Sweden Switzerland (French) Switzerland (German) Turkey Ukraine (Ukrainian) United Kingdom
-
-
Algeria Azerbaijan (Azerbaijani) Azerbaijan (English) Bahrain (English) Benin Botswana Burkina Faso Cameroon Central African Republic Chad Comoros Congo Dem. Rep. Congo (Zaire) Egypt and North East Africa (Arabic) Egypt and North East Africa (English) Equatorial Guinea Francophone Africa Gabon Gambia Ghana Guinea Iraq Israel Ivory Coast Jordan Kenya Kuwait Lebanon Liberia Libya Madagascar Malawi Mali Mauritania Mauritius Mayotte Morocco Mozambique Namibia Niger Nigeria Oman Pakistan Qatar Reunion Saudi Arabia (Arabic) Saudi Arabia (English) Senegal Seychelles Sierra Leone South Africa Swaziland Tanzania Togo Tunisia Uganda United Arab Emirates Yemen Zambia Zimbabwe
-
Vigilohm 12-kanaliges Fehlerortungsgerät mit Modbus - 100-440VAC/DC
IMDIFL12C
Materialpreisgruppe
: DD
3.697,00 €
EAN Code: 3606489504861
Hauptdokumente
| Download | |
|
|
Download |
|
|
Download |
|
|
Download |
|
|
Download |
|
|
Download |
|
|
Download |
|
|
Download |
|
|
Download |
|
|
Download |
|
|
Download |
|
|
Download |
|
|
Download |
Dieses Produkt ist kompatibel mit
Funktionen: Kompatible Produkte
Funktionen (1)
Sensoren: Kompatible Produkte
Sensoren (8)
Spezifikationen
| Hauptmerkmale | |
|---|---|
| Baureihe | Vigilohm |
| Kurzbezeichnung des Geräts | IFL12C |
| Produkt- oder Komponententyp | Isolationsfehlersuchgerät |
| Application | Environment - standard application Marineanwendung |
| Typ der elektrischen Schaltung | Medium |
| Stromkreistyp | Stromkreis |
| Erdungssystem | IT HRG |
| Benutzersprache | Portugiesisch Russisch Chinesisch Französisch Spanisch Italienisch Deutsch Englisch |
| Type of network | 1P + N 3P 3P + N |
| Network load disturbance | Gering verschmutzt | Eingang |
| Netzspannung | 0…1000 V - AC bei 45 - 65 Hz 0…1000 V - DC |
| Anzahl der Kanäle | 12 |
| Messwerttyp | Netzwerk-Isolationswiderstand, Bereich: 200 Ohm bis 250 kOhm |
| Überwachungsfunktion | Detection of toroids connection automatisch Detection of toroids connection Manuell-Modus Detection of IM400 injection current permanent |
Kommunikation & Management |
| Lokale Signalisierung | Gelb Anzeigeleuchte: Isolationsfehler Gelb Blitzlicht Anzeigeleuchte: Kommunikation Grün/rot Anzeigeleuchte: Produktstatus Grün Anzeigeleuchte: zufriedenstellende Isolierung LCD-Anzeige: transienter Fehler |
| Schwellwerteinstellung | Alarm: hoch, mittel, niedrig |
| [tA] Antwortzeit | <= 5 s |
| Self-test | Automatischer Test beim Start und alle 5 Stunden Ferntest Manuell |
| Ausgangskontakt | 1 Wechslerkontakt Standard oder ausfallsicher |
| Ausschaltvermögen | 250 V - AC bei 6 A 48 V - DC bei 1 A |
| Alarm optional delay | 0 - 120 min für alarm |
| Kommunikationsprotokoll | Modbus RS485 | Zusatzmerkmale |
| Alarm pro Kanal | Alarmschwelle: für alle Abgänge |
| Displaytyp | LCD-Anzeige |
| Anschlüsse - Klemmen | Netzteil: abnehmbare Schraubklemmleiste0,2…2,5 mm² Ausgang Relais: abnehmbare Schraubklemmleiste0,2…2,5 mm² Ringwandlereingänge: abnehmbare Schraubklemmleiste0,2…1,5 mm² Kommunikation: abnehmbare Schraubklemmleiste0,2…2,5 mm² |
| Konfigurierbare Filterzeit | 5 s 40 s |
| [tA] Antwortzeit | 1 s 1/5th of set filtering time 8 s 1/5th of set filtering time |
| Analyse der Netzqualität | Transientenerfassung |
| Überspannungskategorie | III 300 V II 600 V |
Leistungsanforderungen |
| Leistungsaufnahme in VA | 26 VA |
| Leistungsaufnahme in W | 10 W |
| [UH,nom] Bemessungs-Betriebsspannung | 100...300 V (LN) AC 50/60 Hz Toleranz: ± 15 % 100...440 V AC 50/60 Hz Toleranz: ± 15 % 80…120 V (LN) AC 400 Hz Toleranz: ± 15 % 100...440 V DC Toleranz: ± 15 % |
| Überstromschutz | 1 A | Abmessungen |
| Montageposition | Horizontal Vertikal |
| Material | Thermoplastisch |
| Produktgewicht | 0,305 kg |
| Abmessungen des Ausschnitts | 92 x 104 mm |
| Höhe | 110 mm |
| Breite | 108 mm |
| Tiefe | 59 mm |
| Installationstyp | Innenraum |
| Montagemodus | Aufsteckbar (DIN-Schiene) Flächenbündig (Platte) |
Montage |
| Schutzart (IP) | Gehäuse: IP20 Vorderseite: IP54 |
| Betriebshöhe | <= 3.000 m |
| Relative Luftfeuchtigkeit | 5…92 % |
| Umgebungstemperatur bei Betrieb | -25…70 °C |
| Umgebungstemperatur bei Lagerung | -40…85 °C |
| Umgebungseigenschaften | Feuchte Wärme, außerhalb Betrieb entspricht IEC 60068-2-30 Feuchte Wärme, bei Betrieb entspricht IEC 60068-2-56 Salznebel entspricht IEC 60068-2-52 Long-term storage class 1K22 entspricht IEC 60721-3-1 Transport class 2K11 entspricht IEC 60721-3-2 Stationary use at weatherprotected locations class 3K24 entspricht IEC 60721-3-3 |
| Mechanical characteristic | Long-term storage class 1M11 entspricht IEC 60721-3-1 Transport class 2M4 entspricht IEC 60721-3-2 Stationary use class 3M11 entspricht IEC 60721-3-3 |
Konformität |
| Verschmutzungsgrad | 2 |
| Standards | IEC 60364-4-41 IEC 61010-1 IEC 60364-5-51 IEC 61557-9 IEC 61557-15 IEC 61326-2-4 UL 61010-1 |
| Produktzertifizierungen | EAC CE DNV-GL UL cULus |
Verpackungseinheiten |
| VPE 1 Art | PCE |
| Anzahl der Geräte pro Packung | 1 |
| Verpackungsgewicht (Lbs) | 550,0 g |
| VPE 1 Höhe | 9,7 cm |
| VPE 1 Breite | 18,2 cm |
| VPE 1 Länge | 13,5 cm |
| VPE 2 Art | S03 |
| VPE 2 Menge | 8 |
| VPE 2 Gewicht | 5,2 kg |
| VPE 2 Höhe | 30,0 cm |
| VPE 2 Breite | 30,0 cm |
| VPE 2 Länge | 40,0 cm | Vertragliche Gewährleistung |
| Garantie (in Monaten) | 18 |
Nachhaltigkeit
Nachhaltigkeit
|
EU-RoHS-Richtlinie
|
Konform mit Ausnahmen EU-RoHS-Deklaration |
|
Quecksilberfrei
|
Ja |
| Verpackung ohne Kunststoff | Nein |
| Verpackung mit Recycling-Karton | Ja |
| Rücknahme | Ja |
| CO2-Bilanz (kg CO2 eq.) | 648 |
| Total lifecycle Carbon footprint | 648 kg CO2 eq. |
| SCIP-Nummer | D3328ed4-45d1-46a9-bf4a-dba261badb1a |
| Carbon footprint of the manufacturing phase [A1 to A3] | 98.205 |
| CO₂-Fußabdruck der Herstellungsphase [A1 bis A3] | 98 kg CO2 eq. |
| Carbon footprint of the distribution phase [A4] | 0.15364 |
| CO₂-Fußabdruck der Distributionsphase [A4] | 0.2 kg CO2 eq. |
| Carbon footprint of the installation phase [A5] | 0.30142 |
| CO₂-Fußabdruck der Installationsphase [A5] | 0.3 kg CO2 eq. |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 548.78 |
| CO₂-Fußabdruck der Nutzungsphase [B2, B3, B4, B6] | 549 kg CO2 eq. |
| Sustainable packaging | Nein |
| Carbon footprint of the end-of-life phase [C1 to C4] | 0.74526 |
| CO₂-Fußabdruck der End-of-Life-Phase [C1 bis C4] | 0.7 kg CO2 eq. |
| WEEE-Kennzeichnung | Das Produkt muss entsprechend bestimmter Hinweise auf Märkten der Europäischen Union entsorgt werden und darf nicht in Haushaltsabfälle gelangen. |
| EU-RoHS-Richtlinie | Freistellungskonform |
| REACh-Verordnung | Produkt beinhaltet besorgniserregende Stoffe (SVHC) über dem Schwellwert |
31 Dokumente
| IMDIFL12C REACh-Erklärung
07/04/25 · Declaration of Conformity (Sustainability) |
0,2 MB | Download |
| IMDIFL12C EU-RoHS-Erklärung
07/04/25 · Declaration of Conformity (Sustainability) |
0,2 MB | Download |
| IMDIFL12C China-RoHS-Erklärung
07/04/25 · Declaration of Conformity (Sustainability) |
0,2 MB | Download |
| Insulation Fault Locator, Circularity Profile, End of Life Instructions 15/03/25 · Circularity Profile | 0,3 MB | Download |
| DoC DE iso contrl Vigilohm 15/03/25 · Declaration of conformity | 0,9 MB | Download |
| UK Declaration of conformity 15/03/25 · Declaration of conformity | 0,2 MB | Download |
| Guide de mise en service pour Vigilohm IFL12C, IFL12MC, IFL12LMC, IFL12MCT, and IFL12LMCT 15/03/25 · User guide | 0,2 MB | Download |
| Vigilohm IFL12C, IFL12MC y IFL12MCT Manual del usuario 15/03/25 · User guide | 0,9 MB | Download |
| Vigilohm IFL12C, IFL12MC, IFL12LMC, IFL12MCT, et IFL12LMCT Manuel de l'utilisateur 15/03/25 · User guide | 0,9 MB | Download |
| PowerLogic Power Monitoring and Control Catalog - Web
15/03/25 · Catalog |
63,2 MB | Download |
| Firmware upgrade using ION Setup for IMD and IFL devices 15/03/25 · User guide | 0,6 MB | Download |
| Vigilohm IFL12C, IFL12MC, IFL12LMC, IFL12MCT, and IFL12LMCT User Manual 15/03/25 · User guide | 20,2 MB | Download |
| Vigilohm IFL12C,IFL12MC,IFL12LMC,IFL12MCT,IFL12LMCT Instruction Sheet
15/03/25 · Instruction sheet |
9,7 MB | Download |
| PowerLogic Insulation Monitoring Devices Technical Datasheet 15/03/25 · Other technical guide | 2,3 MB | Download |
| IFL12 Range: EU Declaration of Conformity 15/03/25 · Declaration of conformity | 0,1 MB | Download |
| EU Declaration of Conformity 15/03/25 · Declaration of conformity | 0,4 MB | Download |
| Manual de puesta en marcha del Vigilohm IFL12C / IFL12MC / IFL12MCT 16/01/25 · User guide | 0,2 MB | Download |
| Guida per la messa in servizio per Vigilohm IFL12C / IFL12MC / IFL12MCT 16/01/25 · User guide | 0,2 MB | Download |
| Vigilohm IFL12C, IFL12MC e IFL12MCT Manuale utente 16/01/25 · User guide | 0,9 MB | Download |
| Commissioning Guide for Vigilohm IFL12C, IFL12MC, IFL12LMC, IFL12MCT, and IFL12LMCT 16/01/25 · User guide | 0,2 MB | Download |
| Inbetriebnahmeanleitung für Vigilohm IFL12C / IFL12MC / IFL12MCT 16/01/25 · User guide | 0,2 MB | Download |
| Vigilohm IFL12C, IFL12MC und IFL12MCT Benutzerhandbuch 16/01/25 · User guide | 0,9 MB | Download |
| 01/01/70 Certificate | 0,0 MB | Download |
| 01/01/70 Catalog | 0,0 MB | Download |
| 01/01/70 Catalog | 0,0 MB | Download |
| 01/01/70 Certificate | 0,0 MB | Download |
| 01/01/70 Certificate | 0,0 MB | Download |
| 01/01/70 Specification sheet | 0,0 MB | Download |
| 01/01/70 Technical illustration | 0,0 MB | Download |
| 01/01/70 CAD | 0,0 MB | Download |
| 01/01/70 Environmental Disclosure | 0,0 MB | Download |