Select your location
-
Most Common Destinations
-
Asia Pacific
Australia Bangladesh Brunei Cambodia China Fiji, Tonga French Polynesia Hong Kong, China India Indonesia (Bahasa) Indonesia (English) Japan Kazakhstan Korea, South Laos Malaysia Maldives Mongolia Mongolia (English) Myanmar (English) New Caledonia New Zealand Papua New Guinea Philippines Singapore Sri Lanka Taiwan, China Thailand (English) Thailand (Thai) Uzbekistan Uzbekistan (English) Vietnam Vietnam (Vietnamese) -
Europe
Albania Austria Belarus Belarus (English) Belgium Belgium (Dutch) Bosnia-Herzegovina Bulgaria Croatia Cyprus Czech Republic Denmark Estonia Finland France Georgia Georgia (English) Germany Greece Hungary Ireland Italy Kosovo Latvia Lithuania Malta Moldavia Montenegro Netherlands North Macedonia Norway Poland Portugal Romania Russia Serbia Slovakia Slovenia Spain Sweden Switzerland (French) Switzerland (German) Turkey Ukraine (Ukrainian) United Kingdom -
Latin America
-
Middle East and Africa
Algeria Azerbaijan (Azerbaijani) Azerbaijan (English) Bahrain (English) Benin Botswana Burkina Faso Cameroon Central African Republic Chad Comoros Congo Dem. Rep. Congo (Zaire) Egypt and North East Africa (Arabic) Egypt and North East Africa (English) Equatorial Guinea Francophone Africa Gabon Gambia Ghana Guinea Iraq Israel Ivory Coast Jordan Kenya Kuwait Lebanon Liberia Libya Madagascar Malawi Mali Mauritania Mauritius Mayotte Morocco Mozambique Namibia Niger Nigeria Oman Pakistan Qatar Reunion Saudi Arabia (Arabic) Saudi Arabia (English) Senegal Seychelles Sierra Leone South Africa Swaziland Tanzania Togo Tunisia Uganda United Arab Emirates Yemen Zambia Zimbabwe -
North America
Aktiver Oberschwingungsfilter, AccuSine PCS+, 235A, 500-600V AC, 3P, N12
PCSP235D6N12
Materialpreisgruppe
: DW
104.196,00 €
EAN Code: 3606480851346
Hauptdokumente
| Download | |
|
|
Download |
|
|
Download |
|
|
Download |
|
|
Download |
|
|
Video anzeigen |
|
|
Download |
|
|
Download |
|
|
Download |
|
|
Download |
|
|
Download |
|
|
Download |
|
|
Download |
Spezifikationen
| Hauptmerkmale | |
|---|---|
| Baureihe | AccuSine |
| Produktname | AccuSine PCS+ |
| Produkt- oder Komponententyp | Aktiver Oberschwingungsfilter | Zusatzmerkmale |
| Netzwerktyp | 3P |
| Netzwerkkonfiguration | 3 oder 4 Drähte |
| Netzspannung | 500…600 V AC |
| Netzwerkfrequenz | 50/60 Hz +/-3 Hz automatische Erfassung |
| Max. zulässige Spannung | 1,1 x Un |
| Neutral Korrektur | Nicht bereitgestellt |
| Effektivwert des Ausgangsstroms | 235 A |
| Blindleistungsangabe | 244 kvar 600 V AC 50/60 Hz |
| Betriebsarten | Korrektur Leistungsfaktor Oberschwingungsauslöschung Netzstromausgleich |
| Installationsort | Innenraum |
| Gehäusemontage | Bodenstehend |
| Schutzart | Leistungsschalterschutz |
| Trennungstyp | Türverriegelung mit Drehgriff |
| Ausschaltvermögen | 100 kA |
| Wärmeabgabe | Rückschacht mit Zwangsbelüftung für hohen Wärmestrom |
| Elektromagnetische Verträglichkeit | Leitungsgebundene elektromagnetische Verträglichkeit, Klasse A entspricht EN 61000-6-4 |
| Zugänglichkeit für den Betrieb | Frontseite |
| Position des Anschlusses | Oben oder unten | Montage |
| Schutzart des Gehäuses | UL Typ 12 |
| Umgebungseigenschaften | Betrieb: 3C2 entspricht IEC 60721-3-3 Betrieb: 3S2 entspricht IEC 60721-3-3 Speicher: 3C3 entspricht IEC 60721-3-3 Speicher: 3S3 entspricht IEC 60721-3-3 |
| Betriebshöhe | <lt/>= 1.000 m 1 % pro 100 m |
| Umgebungstemperatur bei Betrieb | 0…40 °C 0…50 °C Maximum mit Stromreduzierung von 2 % pro °C |
| Relative Luftfeuchtigkeit | 0…95 % |
| Schutz der Leiterplatte | Schutzbeschichtet |
| Normen | CSA C22.2 Nr. 60947-1-07 EN 61000-6-4 EN 60439-1 UL 508 CSA C22.2 Nr. 14 UL 60947-1 |
| Produktzertifizierungen | CE RCM ABS cULus |
| Umgebungstemperatur bei Lagerung | -20…60 °C |
| Produktgewicht | 990 kg |
| Höhe | 2100 mm |
| Breite | 1400 mm |
| Farbe | Hellgrau (RAL 7035) |
| Tiefe | 600 mm | Verpackungseinheiten |
| VPE 1 Art | PCE |
| Anzahl der Geräte pro Packung | 1 |
| Verpackungsgewicht (Lbs) | 916,0 kg |
| VPE 1 Höhe | 233,1 cm |
| VPE 1 Breite | 104,8 cm |
| VPE 1 Länge | 162,9 cm | Vertragliche Gewährleistung |
| Garantie (in Monaten) | 18 |
Nachhaltigkeit
Nachhaltigkeit
|
Quecksilberfrei
|
Ja |
| Verpackung ohne Kunststoff | Nein |
| Rücknahme | Ja |
| SCIP-Nummer | 41f8a5bd-7758-4f6b-8e3f-271055f150ec |
| Sustainable packaging | Nein |
| Verpackung mit Recycling-Karton | Ja |
| WEEE-Kennzeichnung | Das Produkt muss entsprechend bestimmter Hinweise auf Märkten der Europäischen Union entsorgt werden und darf nicht in Haushaltsabfälle gelangen. |
| EU-RoHS-Richtlinie | https://download.schneider-electric.com/files?p_Doc_Ref=PCSP235D6N12_ROHS_DECLARATION&p_enDocType=Declaration+of+Conformity+%28Sustainability%29 |
| REACh-Verordnung | https://download.schneider-electric.com/files?p_Doc_Ref=PCSP235D6N12_REACH_DECLARATION&p_enDocType=Declaration+of+Conformity+%28Sustainability%29 |
| Recyclingfähigkeitspotential in % | 72 |
| Total lifecycle Carbon footprint | 333 ton CO2 eq. |
| Carbon footprint of the manufacturing phase [A1 to A3] | 7375.744448422524 |
| CO₂-Fußabdruck der Herstellungsphase [A1 bis A3] | 7 376 kg CO2 eq. |
| Carbon footprint of the distribution phase [A4] | 673.7606782983488 |
| CO₂-Fußabdruck der Distributionsphase [A4] | 674 kg CO2 eq. |
| Carbon footprint of the installation phase [A5] | 234.08463826484353 |
| CO₂-Fußabdruck der Installationsphase [A5] | 234 kg CO2 eq. |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 323583.6188081576 |
| CO₂-Fußabdruck der Nutzungsphase [B2, B3, B4, B6] | 324 ton CO2 eq. |
| Carbon footprint of the end-of-life phase [C1 to C4] | 1270.0132192989254 |
| CO₂-Fußabdruck der End-of-Life-Phase [C1 bis C4] | 1 270 kg CO2 eq. |
| CO2-Bilanz (kg CO2 eq.) | 333137 |
23 Dokumente
| AccuSine+ · Aktive Netzfilter und Blindleistungssteuerung (Katalog 2021)
15/09/25 · Catalog |
4,3 MB | Download |
| Power Quality
20/08/25 · Brochure |
1,8 MB | Download |
| Electronic VAR control 200 amp 600-690 VAC IP54 Enclosure - TI 03/04/25 · Technical illustration | 0,0 MB | Download |
| PCSP235D6N12 EU-RoHS-Erklärung
22/03/25 · Declaration of Conformity (Sustainability) |
0,2 MB | Download |
| UL Certificate of Compliance - PowerLogic PCS+ 15/03/25 · Certificate | 0,2 MB | Download |
| ABS.PDA-Certificate.2028 - PowerLogic PCS+, PFV+, PCSn, EVC+ 15/03/25 · Certificate | 2,2 MB | Download |
| AccuSine PFV+ 200A, 690 VAC IP54 - 3D CAD 15/03/25 · CAD | 3,0 MB | Download |
| Discover PowerLogic AccuSineTM Power Correction Systems
15/03/25 · Promotional video |
0,2 MB | Video anzeigen |
| PowerLogic™ AccuSine Firmware User Manual 15/03/25 · User guide | 6,9 MB | Download |
| DoC DE upd25 15/03/25 · Certificate | 2,1 MB | Download |
| PowerLogic™AccuSine Firmware Version 004 Benutzerhandbuch 15/03/25 · User guide | 5,6 MB | Download |
| AccuSine PCS+, PCSn, PFV+ Firmware Release 003.000.002
15/03/25 · Firmware |
10,4 MB | Download |
| PowerLogic™ AccuSine PCS+, PFV+, and PCSn User Manual 15/03/25 · User guide | 6,0 MB | Download |
| Installation Manual: AccuSine™ PCS+ Active Harmonic Filter / AccuSine™ PFV+ Electronic VAR Control
15/03/25 · Instruction sheet |
4,6 MB | Download |
| Installation Manual: AccuSine™ PCS+ Active Harmonic Filter / AccuSine™ PFV+ Electronic VAR Control
15/03/25 · Instruction sheet |
4,7 MB | Download |
| Large Enclosure 600-690V IP54-N12 - Dimensional Drawing 15/03/25 · Technical Drawing | 0,4 MB | Download |
| LARGE ENCLOSURE 600-690V IP54-N12 15/12/24 · CAD | 1,7 MB | Download |
| PCSP235D6N12 : Active Harmonic filter 235 amp 500-600 VAC N12 Gehäuse
11/01/23 · Declaration of Conformity (Sustainability) |
0,2 MB | Download |
| 01/01/70 Specification sheet | 0,0 MB | Download |
| 01/01/70 Specification sheet | 0,0 MB | Download |
| 01/01/70 Technical illustration | 0,0 MB | Download |
| 01/01/70 Instruction sheet | 0,0 MB | Download |
| 01/01/70 Catalog | 0,0 MB | Download |