Australia Bangladesh Brunei Cambodia China Fiji, Tonga French Polynesia Hong Kong, China India Indonesia (Bahasa) Indonesia (English) Japan Kazakhstan Korea, South Laos Malaysia Maldives Mongolia Mongolia (English) Myanmar (English) New Caledonia New Zealand Papua New Guinea Philippines Singapore Sri Lanka Taiwan, China Thailand (English) Thailand (Thai) Uzbekistan Uzbekistan (English) Vietnam Vietnam (Vietnamese)
-
Albania Austria Belarus Belarus (English) Belgium Belgium (Dutch) Bosnia-Herzegovina Bulgaria Croatia Cyprus Czech Republic Denmark Estonia Finland France Georgia Georgia (English) Germany Greece Hungary Ireland Italy Kosovo Latvia Lithuania Malta Moldavia Montenegro Netherlands North Macedonia Norway Poland Portugal Romania Russia Serbia Slovakia Slovenia Spain Sweden Switzerland (French) Switzerland (German) Turkey Ukraine (Ukrainian) United Kingdom
-
-
Algeria Azerbaijan (Azerbaijani) Azerbaijan (English) Bahrain (English) Benin Botswana Burkina Faso Cameroon Central African Republic Chad Comoros Congo Dem. Rep. Congo (Zaire) Egypt and North East Africa (Arabic) Egypt and North East Africa (English) Equatorial Guinea Francophone Africa Gabon Gambia Ghana Guinea Iraq Israel Ivory Coast Jordan Kenya Kuwait Lebanon Liberia Libya Madagascar Malawi Mali Mauritania Mauritius Mayotte Morocco Mozambique Namibia Niger Nigeria Oman Pakistan Qatar Reunion Saudi Arabia (Arabic) Saudi Arabia (English) Senegal Seychelles Sierra Leone South Africa Swaziland Tanzania Togo Tunisia Uganda United Arab Emirates Yemen Zambia Zimbabwe
-
Galaxy VXL UPS 1250 kW, 400 V, Start-up 5x8
GVXL1250KHS
Hauptdokumente
Download | |
|
Download |
|
Download |
|
Download |
|
Download |
|
Download |
|
Download |
|
Download |
|
Download |
|
Download |
|
Download |
|
Video anzeigen |
|
Download |
Dieses Produkt ist kompatibel mit
Zubehörteile: Kompatible Produkte

Leistungsmodule: Kompatible Produkte

Battery Accessories: Kompatible Produkte

Batterien: Kompatible Produkte

: Kompatible Produkte

Spezifikationen
Übersicht | |
---|---|
Lieferzeit | Sonderbestellung - Lieferzeit auf Anfrage | Hauptmerkmale |
Haupteingangsspannung | 400 V 3 Phasen 415 V 380 V |
Weitere Eingangsspannung | 400 V 415 V 380 V |
Hauptausgangsspannung | 400 V3 Phasen |
Weitere Ausgangsspannung | 400 V |
Bemessungsleistung in W | 1250 kW |
Nennleistung in VA | 1250 kVA |
Anschlussart der Eingänge | 1861 A |
Batterietyp | VRLA Li-Ion (Lithium-Ionen) |
Baureihe | Galaxy VXL |
Kompatible Produktfamilie | Galaxy VXL | Batterien und Überbrückungszeit |
Batteriespannung | 480 - 576 V DC |
Batteriespannung entladen | 384 V DC |
Max. Kurzschlussstrom | 100 kA |
Leistung Batterieladegerät | 250 kW Volllast | Allgemein |
Max. Bypass-Eingangsstrom | 1823 A |
Bypass-Stromschutz | 1823 A |
Anzahl der Leistungsmodule | 10 |
Redundant | No |
Produkt- oder Komponententyp | Unterbrechungsfreie Stromversorgung (USV) | Abmessungen |
Farbe | Weiß |
Höhe | 1970 mm |
Breite | 1200 mm |
Tiefe | 1000 mm |
Produktgewicht | 1169 kg | Eingang |
Netzwerkfrequenz | 40 - 70 Hz |
Eingangsspannungsgrenzen | 340 - 460 V 400 V |
Max. Eingangsstrom | 2280 A |
Max. Kurzschlussfestigket (Icw) | 100 kA |
Oberschwingungsverzerrung am Eingang | Weniger als 3 % bei Volllast |
Leistungsfaktor der Last | 0,5 voreilend bis 0,5 nacheilend ohne Leistungsminderung | Ausgang |
Max. konfigurierbare Leistung in W | 1250 kW |
Oberschwingungsverzerrung | < 3 % |
Ausgangsfrequenz | 50...60 Hz |
Scheitelfaktor | 3 |
USV-Typ | Online-Doppelwandlung |
Oberschwingungsverzerrung am Ausgang | < 1% linear load and < 5% non-linear load |
Überlastbetrieb des Ausgangs | 10 Minuten bei 125 % und 60 Sekunden bei 150 % |
Bypass-Typ | No bypass |
Max. konfigurierbare Leistung in VA | 1250 VA |
Wellentyp | Sinuswelle | Konformität |
Produktzertifizierungen | IEC 62040-1-1 IEC 62040-2 IEC 62040-3 VFI-SS-111 RoHS |
Normen | IEC 60721-4-2 Level 2M2 | Umgebung |
Umgebungstemperatur bei Betrieb | 0…40 °C |
Relative Luftfeuchtigkeit | 5…90 % nicht kondensierend |
Betriebshöhe | 0 - 3.000 m |
Umgebungstemperatur bei Lagerung | -25…55 °C |
Relative Feuchtigkeit bei Lagerung | 0…95 % nicht kondensierend |
Schutzart (IP) | IP20 |
Wärmeabgabe | 132253 Btu/h | Kommunikation & Management |
Bedienfeld | LCD-Benutzeroberfläche mit Touchscreen | Verpackungseinheiten |
VPE 1 Art | PCE |
Anzahl der Geräte pro Packung | 1 |
VPE 1 Höhe | 215 cm |
VPE 1 Breite | 141 cm |
VPE 1 Länge | 116 cm |
Verpackungsgewicht (Lbs) | 926 kg | Vertragliche Gewährleistung |
Gewährleistung | 1 year on-site repair or replace with factory authorized Start-Up |
Nachhaltigkeit
Nachhaltigkeit
Verpackung mit Recycling-Karton | Ja |
CO2 Fußabdruck am Ende der Betriebsdauer | Energieeffizientes Produkt |
Rücknahme | Nein |
Eingesparte und vermiedene Produktbeiträge | Yes |
CO2-Bilanz (kg CO2 eq.) | 807314 |
EU-RoHS-Richtlinie
|
Konform mit Ausnahmen EU-RoHS-Deklaration |
Quecksilberfrei
|
Ja |
Total lifecycle Carbon footprint | 807 ton CO2 eq. |
Carbon footprint of the manufacturing phase [A1 to A3] | 18118.55420749456 |
CO2 Fußabdruck am Ende der Betriebsdauer | 18 119 kg CO2 eq. |
Carbon footprint of the distribution phase [A4] | 653.9916041399866 |
Durchschnittlicher Prozentsatz der ReponsibleSteel zertifizierten Metalle | 654 kg CO2 eq. |
CO2 Fußabdruck während der Einrichtung | 0 kg CO2 eq. |
Carbon footprint of the use phase [B2, B3, B4, B6] | 785211.2747917486 |
Carbon footprint of the use phase [B2, B3, B4, B6] | 785 ton CO2 eq. |
Sustainable packaging | Nein |
Carbon footprint of the end-of-life phase [C1 to C4] | 3330.121837594932 |
Carbon footprint of the end-of-life phase [C1 to C4] | 3 330 kg CO2 eq. |
Verpackung ohne Kunststoff | Nein, wir haben den Einsatz von Kunststoff in der Verpackung gemäß den Vorschriften und unter Berücksichtigung von Qualitäts- und Sicherheitsstandards minimiert |
WEEE Label | Das Produkt muss entsprechend bestimmter Hinweise auf Märkten der Europäischen Union entsorgt werden und darf nicht in Haushaltsabfälle gelangen. |
26 Dokumente
Network Management Card 4 Galaxy VXL Firmware 15.11.0 Release Notes 11/04/25 · User guide | 0,2 MB | Download |
NMC4 Modbus Register Map: Galaxy VXL 500-1250 kW 11/04/25 · User guide | 0,4 MB | Download |
Galaxy VXL UPS 380/400/415V Operation
24/03/25 · User guide |
8,1 MB | Download |
Galaxy VXL UPS 380/400/415 V Installation
24/03/25 · User guide |
26,0 MB | Download |
Galaxy VXL 500-1250 kW 380/400/415 V UPS Technical Specifications
24/03/25 · Specification guide |
2,4 MB | Download |
GVXL1250KHS EU-RoHS-Erklärung
20/03/25 · Declaration of Conformity (Sustainability) |
0,2 MB | Download |
GVXL1250KHS China-RoHS-Erklärung
20/03/25 · Declaration of Conformity (Sustainability) |
0,2 MB | Download |
EU Declaration of Conformity for Galaxy VXL 18/03/25 · Declaration of conformity | 5,8 MB | Download |
Galaxy VXL 3-phase UPS in 60 Seconds
15/03/25 · Promotional video |
313,2 MB | Video anzeigen |
Galaxy VXL (400 V) certificate of origin 15/03/25 · Certificate of Origin | 0,1 MB | Download |
Galaxy VXL Receiving and Unpacking
15/03/25 · User guide |
6,3 MB | Download |
Galaxy VXL Earthing Principles 15/03/25 · User guide | 9,4 MB | Download |
Network Management Card 4 - Installation Guide
15/03/25 · User guide |
1,6 MB | Download |
Network Management Card 4 - Feature List
15/03/25 · User guide |
0,2 MB | Download |
Network Management Card 4 Security Handbook 15/03/25 · User guide | 0,8 MB | Download |
Befehlszeilenhandbuch USV-Netzwerkmanagement-Karte 4
15/03/25 · User guide |
1,4 MB | Download |
Galaxy VXL UPS 15/03/25 · Environmental Disclosure | 0,5 MB | Download |
Assessing 3-Phase UPS Sustainability with PEP
15/03/25 · Handout |
37,1 MB | Download |
Galaxy_VXL_UPS_500kW_Scalable_to_1250kW_400V_Schneider_Electric_BIM_Model
15/03/25 · BIM Model |
1,0 MB | Download |
Galaxy VXL UPS 15/03/25 · Circularity Profile | 0,3 MB | Download |
Galaxy VXL 500-1250 kW (400 V) Brochure
15/03/25 · Brochure |
16,0 MB | Download |
Galaxy VXL - Broschüre
15/03/25 · Brochure |
3,2 MB | Download |
GVXLX500-1250KHS-Galaxy VXL UPS 500kW scalable to 1250kW 400V
15/03/25 · Technical Drawing |
1,4 MB | Download |
GVXL500-1250KHS-SD GVXL 4Wire 500-1250kW 380-400-415V UPS w Batt One Line
15/03/25 · Technical Drawing |
0,7 MB | Download |
GVXL500-1250KHS-WD GVXL 4Wire 500-1250kW 380-400-415V UPS w Batt Wiring
15/03/25 · Technical Drawing |
0,5 MB | Download |
UKCA Declaration of conformity for Galaxy VXL 15/03/25 · Declaration of conformity | 0,3 MB | Download |