Australia Bangladesh Brunei Cambodia China Fiji, Tonga French Polynesia Hong Kong, China India Indonesia (Bahasa) Indonesia (English) Japan Kazakhstan Korea, South Laos Malaysia Maldives Mongolia Mongolia (English) Myanmar (English) New Caledonia New Zealand Papua New Guinea Philippines Singapore Sri Lanka Taiwan, China Thailand (English) Thailand (Thai) Uzbekistan Uzbekistan (English) Vietnam Vietnam (Vietnamese)
-
Albania Austria Belarus Belarus (English) Belgium Belgium (Dutch) Bosnia-Herzegovina Bulgaria Croatia Cyprus Czech Republic Denmark Estonia Finland France Georgia Georgia (English) Germany Greece Hungary Ireland Italy Kosovo Latvia Lithuania Malta Moldavia Montenegro Netherlands North Macedonia Norway Poland Portugal Romania Russia Serbia Slovakia Slovenia Spain Sweden Switzerland (French) Switzerland (German) Turkey Ukraine (Ukrainian) United Kingdom
-
-
Algeria Azerbaijan (Azerbaijani) Azerbaijan (English) Bahrain (English) Benin Botswana Burkina Faso Cameroon Central African Republic Chad Comoros Congo Dem. Rep. Congo (Zaire) Egypt and North East Africa (Arabic) Egypt and North East Africa (English) Equatorial Guinea Francophone Africa Gabon Gambia Ghana Guinea Iraq Israel Ivory Coast Jordan Kenya Kuwait Lebanon Liberia Libya Madagascar Malawi Mali Mauritania Mauritius Mayotte Morocco Mozambique Namibia Niger Nigeria Oman Pakistan Qatar Reunion Saudi Arabia (Arabic) Saudi Arabia (English) Senegal Seychelles Sierra Leone South Africa Swaziland Tanzania Togo Tunisia Uganda United Arab Emirates Yemen Zambia Zimbabwe
-
MP120NC Thermal PIBCV Actuator, 2-Position (or Modulate under PWM), Normally closed, 24Vac, 120N, IP45
MP120NC-24T
Hauptdokumente
| Download | |
|
|
Download |
|
|
Download |
|
|
Download |
|
|
Download |
|
|
Download |
Spezifikationen
| Hauptmerkmale | |
|---|---|
| Produktreihe Stellantriebe | SmartX Actuator |
| Produkt- oder Komponententyp | Stellglied |
| Stellantriebstyp | Thermoelektrisch |
| Produktserie Stellantriebe | MP120 |
| Produktbestimmung | druckunabhängige Regelventile |
| Halteleistungsaufnahme in W | 2 W |
| Steuersignal | 2-Position (ein/aus) |
| Zielregion | Europa Asien-Pazifik. Australien. |
Zusatzmerkmale |
| Stellglied | Linear |
| Steuerungstyp | Automatische Rückstellung |
| rated supply voltage | 24 V AC/DC |
| Leistungsaufnahme in W | 2 W |
| Hublänge | 6,5 mm |
| [N] Kraft | 120 N |
| [lbf] Kraft | 27 lbf |
| Positionsanzeige | Hubanzeige in der oberen Kappe |
| Leitungslänge | 1,5 m |
| Leitungen und Verbindungen | Abnehmbares Kabel |
| Material | Polykarbonat: Gehäuse | Montage |
| Schutzart (IP) | IP44 |
| Umgebungstemperatur bei Betrieb | 2…50 °C |
| Relative Luftfeuchtigkeit | 0…95 % rF, nicht kondensierend |
| Umgebungstemperatur bei Lagerung | -45…60 °C | Verpackungseinheiten |
| VPE 1 Art | PCE |
| Anzahl der Geräte pro Packung | 1 |
| VPE 1 Höhe | 14,9 cm |
| VPE 1 Breite | 11,2 cm |
| VPE 1 Länge | 5,5 cm |
| Verpackungsgewicht (Lbs) | 160 g |
| VPE 2 Art | S02 |
| VPE 2 Menge | 21 |
| VPE 2 Höhe | 15 cm |
| VPE 2 Breite | 30 cm |
| VPE 2 Länge | 40 cm |
| VPE 2 Gewicht | 3,689 kg | Vertragliche Gewährleistung |
| Garantie (in Monaten) | 18 |
Nachhaltigkeit
Nachhaltigkeit
|
EU-RoHS-Richtlinie
|
Konform mit Ausnahmen EU-RoHS-Deklaration |
|
Quecksilberfrei
|
Ja |
| Verpackung ohne Kunststoff | Nein |
| Verpackung mit Recycling-Karton | Ja |
| Rücknahme | Ja |
| CO2-Bilanz (kg CO2 eq.) | 25 |
| Total lifecycle Carbon footprint | 25 kg CO2 eq. |
| Carbon footprint of the manufacturing phase [A1 to A3] | 1.9384540611262226 |
| CO2 Fußabdruck am Ende der Betriebsdauer | 2 kg CO2 eq. |
| Carbon footprint of the distribution phase [A4] | 0.06925095020031408 |
| Durchschnittlicher Prozentsatz der ReponsibleSteel zertifizierten Metalle | 0.1 kg CO2 eq. |
| Carbon footprint of the installation phase [A5] | 0.016688724042581343 |
| CO2 Fußabdruck während der Einrichtung | 0 kg CO2 eq. |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 23.09621803230775 |
| Carbon footprint of the use phase [B2, B3, B4, B6] | 23 kg CO2 eq. |
| Sustainable packaging | Nein |
| Carbon footprint of the end-of-life phase [C1 to C4] | 0.373443524504752 |
| Carbon footprint of the end-of-life phase [C1 to C4] | 0.4 kg CO2 eq. |
| WEEE-Kennzeichnung | Das Produkt muss entsprechend bestimmter Hinweise auf Märkten der Europäischen Union entsorgt werden und darf nicht in Haushaltsabfälle gelangen. |
| EU-RoHS-Richtlinie | Freistellungskonform |
6 Dokumente
| MP120NC Thermal PIBCV Actuator, 2-Position
21/03/25 · Circularity Profile |
0,7 MB | Download |
| MP120NC Thermal PIBCV Actuator, 2-Position
21/03/25 · Environmental Disclosure |
0,6 MB | Download |
| SpaceLogic MP120 Two Position Thermal Actuators for VP228E/ VP229E SmartX PIBCV, DN10-32 Specification Sheet
15/03/25 · Other technical guide |
0,8 MB | Download |
| MP120NC-24T REACh-Erklärung
23/01/25 · Declaration of Conformity (Sustainability) |
0,2 MB | Download |
| MP120NC-24T EU-RoHS-Erklärung
23/01/25 · Declaration of Conformity (Sustainability) |
0,2 MB | Download |
| EU Declaration of Conformity for MP120 family 15/11/24 · Declaration of conformity | 0,0 MB | Download |